Model: greenBOX Max, product EG.157 |
Certification: CE, CA UK (LVD - Low Voltage Directive, EMC - Electromagnetic Compatibility Directive); UL per request |
User Interface: built-in 15.6" touch screen; built-in web server, user interface is accessible via any connected device with browser; remote access via internet; by using modern internet technologies Web User Interface response is immediate and fluent, scalable to different screen resolution. |
Software Updates: Software is automatically updatable via internet connection (Ethernet port) |
Size: Approx. 18” width x 21” height x 7” deep (458 mm x 534 mm x 178 mm), green painted metal type 1 enclosure intended for a wall installation (wall mouting plate is included). |
Weight: Approx 45 Lb (21 kg) |
Power Supply: Two IEC-60230 C14 power sockets for C13 IEC cable, 120 – 240 V AC, 50-60 Hz; Two redundant 480 W, peak 720W power supplies CE, UK CA, UL508A, UL listed, EMI input filter. |
Modbus Ports: Six Modbus over RS485 for Ecogate Smart gates, and for Ecogate Power MASTER Variable Frequency Drives; and for other Modbus devices (air velocity sensors, pressure transmitters, temperature sensors etc.), the 24V DC is provided for Ecogate gates and other Modbus devices, each 24V DC power output is electronically protected, limit is set to 3.3A, and adjustable up to 4A in user interface. |
Front Panel Touchscreen: 15.6” OLED panel, resolution 3840 x 2160 (4k), brightness 400 cd/m2, contrast ratio 100k:1, 178 degree viewing angle, 60 Hz refresh rate, multipoint touch.
|
Ecogate Compatibility: Ecogate Smart gates 2” to 26” ( + metric 120, 140, 160mm), Ecogate VOLT or current sensors, Ecogate Power Master variable frequency drives for 10 to 400 HP fan motors, Ecogate Master and Sensor cables. |
Inputs: Eight optically isolated digital inputs (24V DC provided by greenBOX, current 10mA); function selectable from the listbox in user interface. |
Outputs: Eight free (dry) contacts, three Normally Open (NO), one Normally Open and Normally Closed (NO and NC); function selectable from the listbox in user interface. Maximal 24V DC or AC, 1A. Two outputs for status LED lights: Error (Red), Warning (Orange), OK (Green), maximal total current 0.37A, 24V DC (8.8W). |
Other Terminals: Ethernet up to 1Gbps, USB for external keyboard/mouse. |
Settings: Metric or Imperial units selection, time zone selection, gate timings (on delay, off delay), gate diameters, design drop air velocity, minimum airflow to maintain transport air velocity as a percentage of total air volume in many duct zones, negative pressure compensation (for the workstations at the end of ducting), dust collector on delay (0-99 sec) and dust collector shut-off delay (0 to 99 minutes), variable frequency drive minimal and maximum RPM, security functions (configurable in setup: all gates can be open or closed in stop mode), CLEANING function (to sweep duct in regular intervals, or at system stop); Fan and filter Pressure monitoring with separate Warning and Error levels both for Minimum and Maximum pressure; Savings evaluation based on baseline power value; Utilization of workstations evaluation (% of shift time); greenBOX power supply and temperature monitoring; VFD monitoring (communication, inputs, outputs). |