greenBOX

small logo

greenBOX

The greenBOX® is a microprocessor based unit that controls up to eight workstations with ECOGATE ® gates and a central dust collector. It has automatic and manual control modes (the manual mode allows the user to open/close gates by pressing a button on the greenBOX® panel). Switched power output for central dust collector. Eight control channels (input/outputs) to connect vibrating sensors ECOde and ECOGATE® gates. Saves time, energy and your health.

The greenBOX control elements : Push buttons to control gates 1 - 8 manually · Dust collector control switch: Manual or Automatic mode.
The greenBOX indicators : Gate 1 - 8 Open/Close (8x LEDs), · Dust collector ON/OFF (1 LED) · Power supply ON (1 LED)
The greenBOX terminals · Gate 1 - 8: terminal blocks · Remote button: terminal block  · Power input: screw terminals 25 Amp max. · Dust collector power: screw terminals 25 Amp max.

Key Features

  • The vibrating ECOde ® sensor continuously monitors your machinery. Whenever a machine is turned on, the greenBOX ® opens the corresponding gate and turns the dust collector on. When the machine is turned off, the gate closes and the dust collector is stopped. This means no remote control is necessary.
  • The system is automatically ON when you want it to be on, and OFF when you want it to be off. No more walking across your shop twice for every machine usage. You can forget about your dust collecting system and focus on your work.
  • greenBOX® is compatible with both the ECOde sensor and the toroid sensor (reads current to the machine).
  • Selectable "Dust collector OFF delay function" (0, 2, 5, 10 minutes).
  • Dust collector compatibility: up to 1 HP one phase 115V, 2 HP two phase 230V (a larger dust collector can be connected via external contactor, see EG 400 power relay.

MODEL

ECOGATE, Part No. EG101

CASE

Size: approx. 11,42" x 5,91" x 2,95" (without control elements)
Grounded metal box, green painted.

WEIGHT

Approx. 4,7 Lb (2,1 kg)

POWER SUPPLY

115 or 230 V, internally switchable,
50 or 60 Hz (115 V 1-phase, 230 V 2-phase)

POWER CONSUMPTION

Internal electronics: 20 VA max., stand-by 4.5VA,
total (incl. dust collector consumption) max. 25 A

FUSE

For internal electronics only, 5 mm x 20 mm, T 125 mA (230V), T250 mA (115V) , slow-blow, according IEC 60127 2/3

OPERATING & STORAGE CONDITIONS

For indoor use only.

Operating temperature: 23° F to 104° F (-5° C to 40° C)

Operating humidity: 10% to 90% (non-condensing)

Storage temperature: 5° F to 140° F (-15° C to 60° C)

Storage humidity: 10% to 90% (non-condensing)

POWER INPUT

Power supply 115V or 230V, 25A max., connectors: screw terminal, 10-30 AWG

SWITCHED POWER OUTPUT

For dust collector - one or two phase, connector: screw terminal, 10-30 AWG, 1-phase 115V max for a 1 HP motor, 2-phase 230V max. for a 2 HP motor

LOW-VOLTAGE INPUTS/OUTPUTS

Max. 24V DC, eight Input/Output channels for gates and sensors, daisy-chain input/output, remote switch for gate #8, connectors: OST, Pluggable Terminal Blocks, 22-16 AWG (0.5 -1.5 mm²)

FRONT PANEL CONTROL ELEMENTS

a. / Push button for MANUAL mode selection

b. / Eight push buttons for manual control of gates 1..8 and setup function access

FRONT PANEL INDICATORS

a/ "POWER" indicator
b/ "DUST COLLECTOR ON" indicator
c/ "MANUAL MODE ON" indicator
d/ eight indicators "1..8" corresponding to the OPEN or CLOSED position of the individual gates, and setup within the various functions

 

 

INTERNAL SETUP ELEMENTS

a/ gate "RUN TIME" (1-4.8 sec. selectable by software)

b/ "DUST COLLECTOR OFF DELAY TIME"
(0 to 25 minutes selectable by software)

c/ " GATES TO REMAIN OPEN"
(for cyclone units, to maintain minimum airflow)

d/ "SENSOR FALSE SIGNAL TOLERANCE"

e/ "SENSOR SIGNAL DROPOUTS TOLERANCE"
e/ "VOLTAGE SELECTOR 115 OR 230V)

SENSOR TYPE

ECOde piezoelectric (read machine vibrations), optional toroidal type ECOde /t (read AC current to the machine motor)

DOWNLOAD A BROCHURE


ECOde ® , electronic vibrating sensor EG306

MODEL

ECOGATE, Part No. EG306

SIZE

Size approx. 1.75" x 0.66" (without cable)

WEIGHT

Approx. 0.8 ounce (25 g)

MOUNTING

by VELCRO on the machine

PRINCIPLE

Piezo-electric, reads machine vibrations

CABLE

Two wire cable to connect sensor to the ECOGATE ® gate, 8 ft long

Note: Using this version of the greenBOX® in a commercial environment voids the warranty.

Contact Us | ©1998-2008 Ecogate, Inc. All rights reserved. US Pat. No. 6,012,199, 7,146,677, other patents pending. Ecogate, Ecogate logo and greenBOX are registered trademarks of Ecogate, Inc. Specification are subject to change without prior notice.| Designed and coded by Marek Litomisky and Krystof Litomisky.