DIMENSIONS |
Approx. diameter 1.25" x height 0.25", hole for wire 0.25" |
WEIGHT |
0.9 oz |
WIRES |
2.5" long with screw terminals (should be connected to gate sensor input) |
The Toroidal Sensor, EG313
The toroidal sensor is optional accessories for the ECOGATE Set, or the greenBOX® unit. It reads current to the motor of the workstation. Because of this, it should be used for "silent" machines without vibrations (where the signal level from standard ECOde sensors is low). Electrical power installation required.
The toroidal sensor can be installed inside the workstation (for example, in the joint electrical box for the motor). It can also be installed in the wall electrical box with the socket for the workstation. One phase wire should be installed inside of the wall of the toroidal sensor. Because of this, power installation is necessary.
Key Benefits
- reads current to the motor of the workstation.
- same low voltage connection as a standard ECOde sensor (same connector and cable)
- can be mounted in the electrical box
Power relay, EG400
Power relay is optional accessories for the greenBOX® unit. It should be used if your dust collector is larger than 1 HP (at 115V) or larger than 2 HP (at 230V). Power relay contactor can be used for 1-phase, 2-phase, and 3-phase installations.
|
The power relay, as delivered by Ecogate, uses a 115 AC control coil. Because of this, the greenBOX® unit must be switched to a 115 V power supply (control coil is connected to the power output of the greenBOX® unit). |
||||||||||||
|